Interface for the Failover Link

You can use an unused data interface (physical, or EtherChannel) as the failover link; however, you cannot specify an interface that is currently configured with a name. You cannot use a data management interface if the interface is configured for communication with Security Cloud Control. You also cannot use a subinterface. The failover link interface is not configured as a normal networking interface; it exists for failover communication only. This interface can only be used for the failover link (and also for the state link).

The Firewall Threat Defense does not support sharing interfaces between user data and the failover link.


 
When using an EtherChannel as the failover or state link, you must confirm that the same EtherChannel with the same member interfaces exists on both devices before establishing high availability.

See the following guidelines for the failover link:

  • Firepower 4100/9300—You cannot use the management-type interface for the failover link.

  • See the following guidelines for sizing the link.

    Table 1. Failover Link Size

    Model

    Interface Size for Combined Failover and State Link

    Firepower 1010

    1 Gbps

    Firepower 1100

    1 Gbps

    Secure Firewall 1200

    1 Gbps

    Secure Firewall 3100

    Secure Firewall 3105—1 Gbps

    Secure Firewall 3110—1 Gbps

    Secure Firewall 3120—1 Gbps

    Secure Firewall 3130—10 Gbps

    Secure Firewall 3140—10 Gbps

    Firepower 4100

    10 Gbps

    Secure Firewall 4200

    10 Gbps

    Firepower 9300

    10 Gbps

The alternation frequency is equal to the unit hold time.


 

If you have a large configuration and a low unit hold time, alternating between the member interfaces can prevent the secondary unit from joining/re-joining. In this case, disable one of the member interfaces until after the secondary unit joins.

For an EtherChannel used as the failover link, to prevent out-of-order packets, only one interface in the EtherChannel is used. If that interface fails, then the next interface in the EtherChannel is used. You cannot alter the EtherChannel configuration while it is in use as a failover link.